Replacement of fire alarm initiating devices and wires

Contractor shall provide all labor, materials, equipment, supplies and supervision to perform the following work: Replacement of fire alarm initiating devices and wires in Building 100, DLA Distribution San Joaquin CA (DDJC), Tracy Site, 25600 South Chrisman Rd, Tracy CA 95304.

Notice typePresolicitation: Heads-up: the agency plans to post a bid soon. Get ready now.
Who's buyingDla Distribution, Defense Logistics Agency
WhereTracy, California
DeadlineNo deadline listed. Check the official posting.
Who can bidOnly small businesses can bid
IndustryNAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors)
Estimated size$250K to $500K
Solicitation #SP3300-16-B-0009
PostedFri, Jul 15, 2016
ContactMogen Gilson, [email protected]

Heads-up: Site visit or pre-bid meeting mentioned · Must be registered in SAM.gov

Open the official posting

From the notice

Contractor shall provide all labor, materials, equipment, supplies and supervision to perform the following work: Replacement of fire alarm initiating devices and wires in Building 100, DLA Distribution San Joaquin CA (DDJC), Tracy Site, 25600 South Chrisman Rd, Tracy CA 95304. The following summary of work is for the purpose of general information and is not intended to include and describe every feature or item or to define the scope of work. It is expected that the contractor will visit the site of work and thoroughly familiarize himself with the conditions existing there. Failure on the part of the contractor to acquaint himself with the site conditions will not be sufficient reason for any increase in contract price. •· Replace existing Apollo-Series software protocol devices with new Velociti-Series addressable devices. •· Replace conventional initiating circuit copper wiring with new addressable communication cables. •· Replace existing fire sprinkler flow & tamper switches monitor modules with new Velociti-series addressable devices. •· Replace all existing manual pull stations with new Velociti-series addressable stations. •· Replace all existing smoke, duct & heat detection devices with new Velociti-series addressable devices. •· Provide all device circuit terminations, final connections, testing, labeling as required. •· Provide submittals, as-built drawings, test reports, guarantees & closeouts as required for approvals. Perform final programming, provide operator